{"id":1553,"date":"2017-04-14T15:32:51","date_gmt":"2017-04-14T22:32:51","guid":{"rendered":"https:\/\/nuzeal.com\/?p=1553"},"modified":"2017-04-14T15:32:51","modified_gmt":"2017-04-14T22:32:51","slug":"us-fcc-new-kdbs-guidance-for-part-15-intentional-radiators","status":"publish","type":"post","link":"https:\/\/nuzeal.com\/index.php\/2017\/04\/14\/us-fcc-new-kdbs-guidance-for-part-15-intentional-radiators\/","title":{"rendered":"US \u2013 FCC New KDBs &#8211; Guidance for Part 15 Intentional Radiators"},"content":{"rendered":"<p><a href=\"https:\/\/i0.wp.com\/nuzeal.com\/wp-content\/uploads\/united_states_of_america.png?ssl=1\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-1039 alignleft\" src=\"https:\/\/i0.wp.com\/nuzeal.com\/wp-content\/uploads\/united_states_of_america.png?resize=191%2C100&#038;ssl=1\" alt=\"united_states_of_america\" width=\"191\" height=\"100\" \/><\/a>The FCC Office of Engineering and Technology (OET) has published a two new KDBs related to measurement procedures for intentional radiators covered by Part 15 rules.<\/p>\n<table style=\"border-color: #03c4eb; width: 717px;\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"border-color: #03c4eb; width: 126px;\"><strong>Publication Number<\/strong><\/td>\n<td style=\"border-color: #03c4eb; width: 272.05px;\"><strong>Question<\/strong><\/td>\n<td style=\"border-color: #03c4eb; width: 305.95px;\"><strong>Answer<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"border-color: #03c4eb; width: 126px;\"><a href=\"https:\/\/apps.fcc.gov\/oetcf\/kdb\/forms\/FTSSearchResultPage.cfm?id=20476&amp;switch=P\" target=\"_blank\">913591<\/a><\/td>\n<td style=\"border-color: #03c4eb; text-align: left; width: 272.05px;\"><span class=\"fontstyle0\">What is the procedure for making band-edge measurements for a Part 15 intentional radiator?<\/span><\/td>\n<td style=\"border-color: #03c4eb; text-align: left; width: 305.95px;\"><span class=\"fontstyle0\">Measurement procedures for band-edge testing are provided in Subclause 6.10 of ANSI Standard C63.10-2013.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-color: #03c4eb; width: 126px;\"><a href=\"https:\/\/apps.fcc.gov\/oetcf\/kdb\/forms\/FTSSearchResultPage.cfm?id=21124&amp;switch=P\" target=\"_blank\">558074<\/a><\/td>\n<td style=\"border-color: #03c4eb; text-align: left; width: 272.05px;\"><span class=\"fontstyle0\">What are the test procedures for measuring Digital Transmission System (DTS) devices subject to the requirements in Section 15.247?<\/span><\/td>\n<td style=\"border-color: #03c4eb; text-align: left; width: 305.95px;\"><span class=\"fontstyle0\">Test procedures for measuring Digital Transmission System (DTS) are provided in the attachment 558074 D01 DTS Meas Guidance v04 and in Clause 11 of ANSI C63.10-2013. The publication version 558074 D01 DTS Meas Guidance v03 was used in the development &#8230;<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The FCC Office of Engineering and Technology (OET) has published a two new KDBs related to measurement procedures for intentional radiators covered by Part 15 rules. Publication Number Question Answer &#8230;<\/p>\n","protected":false},"author":1,"featured_media":1039,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[3],"tags":[10,5,12],"class_list":["post-1553","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-compliance-news","tag-fcc","tag-srd","tag-wlan"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/nuzeal.com\/wp-content\/uploads\/united_states_of_america.png?fit=191%2C100&ssl=1","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/posts\/1553","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/comments?post=1553"}],"version-history":[{"count":1,"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/posts\/1553\/revisions"}],"predecessor-version":[{"id":1554,"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/posts\/1553\/revisions\/1554"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/media\/1039"}],"wp:attachment":[{"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/media?parent=1553"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/categories?post=1553"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nuzeal.com\/index.php\/wp-json\/wp\/v2\/tags?post=1553"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}